mirror of
https://github.com/janeczku/calibre-web
synced 2024-12-26 10:00:37 +00:00
293 lines
9.9 KiB
Python
293 lines
9.9 KiB
Python
#!/usr/bin/env python
|
|
#
|
|
# Copyright 2011 Facebook
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
"""Utilities for working with multiple processes, including both forking
|
|
the server into multiple processes and managing subprocesses.
|
|
"""
|
|
|
|
from __future__ import absolute_import, division, print_function, with_statement
|
|
|
|
import errno
|
|
import multiprocessing
|
|
import os
|
|
import signal
|
|
import subprocess
|
|
import sys
|
|
import time
|
|
|
|
from binascii import hexlify
|
|
|
|
from tornado import ioloop
|
|
from tornado.iostream import PipeIOStream
|
|
from tornado.log import gen_log
|
|
from tornado.platform.auto import set_close_exec
|
|
from tornado import stack_context
|
|
|
|
try:
|
|
long # py2
|
|
except NameError:
|
|
long = int # py3
|
|
|
|
|
|
def cpu_count():
|
|
"""Returns the number of processors on this machine."""
|
|
try:
|
|
return multiprocessing.cpu_count()
|
|
except NotImplementedError:
|
|
pass
|
|
try:
|
|
return os.sysconf("SC_NPROCESSORS_CONF")
|
|
except ValueError:
|
|
pass
|
|
gen_log.error("Could not detect number of processors; assuming 1")
|
|
return 1
|
|
|
|
|
|
def _reseed_random():
|
|
if 'random' not in sys.modules:
|
|
return
|
|
import random
|
|
# If os.urandom is available, this method does the same thing as
|
|
# random.seed (at least as of python 2.6). If os.urandom is not
|
|
# available, we mix in the pid in addition to a timestamp.
|
|
try:
|
|
seed = long(hexlify(os.urandom(16)), 16)
|
|
except NotImplementedError:
|
|
seed = int(time.time() * 1000) ^ os.getpid()
|
|
random.seed(seed)
|
|
|
|
|
|
def _pipe_cloexec():
|
|
r, w = os.pipe()
|
|
set_close_exec(r)
|
|
set_close_exec(w)
|
|
return r, w
|
|
|
|
|
|
_task_id = None
|
|
|
|
|
|
def fork_processes(num_processes, max_restarts=100):
|
|
"""Starts multiple worker processes.
|
|
|
|
If ``num_processes`` is None or <= 0, we detect the number of cores
|
|
available on this machine and fork that number of child
|
|
processes. If ``num_processes`` is given and > 0, we fork that
|
|
specific number of sub-processes.
|
|
|
|
Since we use processes and not threads, there is no shared memory
|
|
between any server code.
|
|
|
|
Note that multiple processes are not compatible with the autoreload
|
|
module (or the debug=True option to `tornado.web.Application`).
|
|
When using multiple processes, no IOLoops can be created or
|
|
referenced until after the call to ``fork_processes``.
|
|
|
|
In each child process, ``fork_processes`` returns its *task id*, a
|
|
number between 0 and ``num_processes``. Processes that exit
|
|
abnormally (due to a signal or non-zero exit status) are restarted
|
|
with the same id (up to ``max_restarts`` times). In the parent
|
|
process, ``fork_processes`` returns None if all child processes
|
|
have exited normally, but will otherwise only exit by throwing an
|
|
exception.
|
|
"""
|
|
global _task_id
|
|
assert _task_id is None
|
|
if num_processes is None or num_processes <= 0:
|
|
num_processes = cpu_count()
|
|
if ioloop.IOLoop.initialized():
|
|
raise RuntimeError("Cannot run in multiple processes: IOLoop instance "
|
|
"has already been initialized. You cannot call "
|
|
"IOLoop.instance() before calling start_processes()")
|
|
gen_log.info("Starting %d processes", num_processes)
|
|
children = {}
|
|
|
|
def start_child(i):
|
|
pid = os.fork()
|
|
if pid == 0:
|
|
# child process
|
|
_reseed_random()
|
|
global _task_id
|
|
_task_id = i
|
|
return i
|
|
else:
|
|
children[pid] = i
|
|
return None
|
|
for i in range(num_processes):
|
|
id = start_child(i)
|
|
if id is not None:
|
|
return id
|
|
num_restarts = 0
|
|
while children:
|
|
try:
|
|
pid, status = os.wait()
|
|
except OSError as e:
|
|
if e.errno == errno.EINTR:
|
|
continue
|
|
raise
|
|
if pid not in children:
|
|
continue
|
|
id = children.pop(pid)
|
|
if os.WIFSIGNALED(status):
|
|
gen_log.warning("child %d (pid %d) killed by signal %d, restarting",
|
|
id, pid, os.WTERMSIG(status))
|
|
elif os.WEXITSTATUS(status) != 0:
|
|
gen_log.warning("child %d (pid %d) exited with status %d, restarting",
|
|
id, pid, os.WEXITSTATUS(status))
|
|
else:
|
|
gen_log.info("child %d (pid %d) exited normally", id, pid)
|
|
continue
|
|
num_restarts += 1
|
|
if num_restarts > max_restarts:
|
|
raise RuntimeError("Too many child restarts, giving up")
|
|
new_id = start_child(id)
|
|
if new_id is not None:
|
|
return new_id
|
|
# All child processes exited cleanly, so exit the master process
|
|
# instead of just returning to right after the call to
|
|
# fork_processes (which will probably just start up another IOLoop
|
|
# unless the caller checks the return value).
|
|
sys.exit(0)
|
|
|
|
|
|
def task_id():
|
|
"""Returns the current task id, if any.
|
|
|
|
Returns None if this process was not created by `fork_processes`.
|
|
"""
|
|
global _task_id
|
|
return _task_id
|
|
|
|
|
|
class Subprocess(object):
|
|
"""Wraps ``subprocess.Popen`` with IOStream support.
|
|
|
|
The constructor is the same as ``subprocess.Popen`` with the following
|
|
additions:
|
|
|
|
* ``stdin``, ``stdout``, and ``stderr`` may have the value
|
|
``tornado.process.Subprocess.STREAM``, which will make the corresponding
|
|
attribute of the resulting Subprocess a `.PipeIOStream`.
|
|
* A new keyword argument ``io_loop`` may be used to pass in an IOLoop.
|
|
"""
|
|
STREAM = object()
|
|
|
|
_initialized = False
|
|
_waiting = {}
|
|
|
|
def __init__(self, *args, **kwargs):
|
|
self.io_loop = kwargs.pop('io_loop', None) or ioloop.IOLoop.current()
|
|
to_close = []
|
|
if kwargs.get('stdin') is Subprocess.STREAM:
|
|
in_r, in_w = _pipe_cloexec()
|
|
kwargs['stdin'] = in_r
|
|
to_close.append(in_r)
|
|
self.stdin = PipeIOStream(in_w, io_loop=self.io_loop)
|
|
if kwargs.get('stdout') is Subprocess.STREAM:
|
|
out_r, out_w = _pipe_cloexec()
|
|
kwargs['stdout'] = out_w
|
|
to_close.append(out_w)
|
|
self.stdout = PipeIOStream(out_r, io_loop=self.io_loop)
|
|
if kwargs.get('stderr') is Subprocess.STREAM:
|
|
err_r, err_w = _pipe_cloexec()
|
|
kwargs['stderr'] = err_w
|
|
to_close.append(err_w)
|
|
self.stderr = PipeIOStream(err_r, io_loop=self.io_loop)
|
|
self.proc = subprocess.Popen(*args, **kwargs)
|
|
for fd in to_close:
|
|
os.close(fd)
|
|
for attr in ['stdin', 'stdout', 'stderr', 'pid']:
|
|
if not hasattr(self, attr): # don't clobber streams set above
|
|
setattr(self, attr, getattr(self.proc, attr))
|
|
self._exit_callback = None
|
|
self.returncode = None
|
|
|
|
def set_exit_callback(self, callback):
|
|
"""Runs ``callback`` when this process exits.
|
|
|
|
The callback takes one argument, the return code of the process.
|
|
|
|
This method uses a ``SIGCHILD`` handler, which is a global setting
|
|
and may conflict if you have other libraries trying to handle the
|
|
same signal. If you are using more than one ``IOLoop`` it may
|
|
be necessary to call `Subprocess.initialize` first to designate
|
|
one ``IOLoop`` to run the signal handlers.
|
|
|
|
In many cases a close callback on the stdout or stderr streams
|
|
can be used as an alternative to an exit callback if the
|
|
signal handler is causing a problem.
|
|
"""
|
|
self._exit_callback = stack_context.wrap(callback)
|
|
Subprocess.initialize(self.io_loop)
|
|
Subprocess._waiting[self.pid] = self
|
|
Subprocess._try_cleanup_process(self.pid)
|
|
|
|
@classmethod
|
|
def initialize(cls, io_loop=None):
|
|
"""Initializes the ``SIGCHILD`` handler.
|
|
|
|
The signal handler is run on an `.IOLoop` to avoid locking issues.
|
|
Note that the `.IOLoop` used for signal handling need not be the
|
|
same one used by individual Subprocess objects (as long as the
|
|
``IOLoops`` are each running in separate threads).
|
|
"""
|
|
if cls._initialized:
|
|
return
|
|
if io_loop is None:
|
|
io_loop = ioloop.IOLoop.current()
|
|
cls._old_sigchld = signal.signal(
|
|
signal.SIGCHLD,
|
|
lambda sig, frame: io_loop.add_callback_from_signal(cls._cleanup))
|
|
cls._initialized = True
|
|
|
|
@classmethod
|
|
def uninitialize(cls):
|
|
"""Removes the ``SIGCHILD`` handler."""
|
|
if not cls._initialized:
|
|
return
|
|
signal.signal(signal.SIGCHLD, cls._old_sigchld)
|
|
cls._initialized = False
|
|
|
|
@classmethod
|
|
def _cleanup(cls):
|
|
for pid in list(cls._waiting.keys()): # make a copy
|
|
cls._try_cleanup_process(pid)
|
|
|
|
@classmethod
|
|
def _try_cleanup_process(cls, pid):
|
|
try:
|
|
ret_pid, status = os.waitpid(pid, os.WNOHANG)
|
|
except OSError as e:
|
|
if e.args[0] == errno.ECHILD:
|
|
return
|
|
if ret_pid == 0:
|
|
return
|
|
assert ret_pid == pid
|
|
subproc = cls._waiting.pop(pid)
|
|
subproc.io_loop.add_callback_from_signal(
|
|
subproc._set_returncode, status)
|
|
|
|
def _set_returncode(self, status):
|
|
if os.WIFSIGNALED(status):
|
|
self.returncode = -os.WTERMSIG(status)
|
|
else:
|
|
assert os.WIFEXITED(status)
|
|
self.returncode = os.WEXITSTATUS(status)
|
|
if self._exit_callback:
|
|
callback = self._exit_callback
|
|
self._exit_callback = None
|
|
callback(self.returncode)
|